NSA2018 : Amending Network Standard NS100 Field Recording of Network Assets
This Network Standard sets out the requirements of recording as-built asset information for Ausgrid’s transmission and distribution networks, and third-party fibre assets interacting with company assets.
NSA2017 : Amending Network Standard NS171 Firestopping in Substations
Amending Network Standard NS171 Firestopping in Substations
NSA2016 : Amending Network Standard NS187 Passive Fire Mitigation Design of Major Substations
This Network Standard details the minimum levels of passive fire protection systems at Ausgrid’s major substations.
NSA2015 : Amending Network Standard NS149 Drawings content for Chamber Type Substations Control Points Cable Risers and Ductlines
Amending Network Standard NS149 Drawings content for Chamber Type Substations Control Points Cable Risers and Ductlines
NSA2014 : Amending Network Standard NS145 Pole Inspection and Treatment
Amending Network Standard NS145 Pole Inspection and Treatment
NSA2013 : Amending Network Standard NS177 11kV Joints (Including Transition Joints) and Terminations -Polymeric Insulated Cables
Amending Network Standard NS177, 11kV Joints (Including Transition Joints) and Terminations - Polymeric Insulated Cables
NSA2012 : Amending Network Standard NS129 11KV Joints and Terminations - Paper Insulated Lead Covered Cables
Amending Network Standard NS129, 11kV Joints and Terminations - Paper Insulated Lead Covered Cables
NSA2011 : Announcing Network Standard NS270 Stray Direct Current Management
The purpose of this document is to minimise the risk of corrosion to Ausgrid assets due to stray direct current.
NSA2010 : Amending Network Standard NS148 Overhead Line Support, Street Light Column, Pit and Pillar Labelling
This Network Standard specifies the requirements and procedure for allocating and installing identification numbers on overhead line supports, street lighting columns, pits, and pillars and ancillary assets in Ausgrid’s supply area.
NSA2009 : Amending Network Standard NS174C Environmental Handbook for Construction and Maintenance
This Handbook forms part of Ausgrid’s Environmental Management System (EMS) and provides guidance for complying with our environmental responsibilities.
NSA2008 : Amending Network Standard NS114 Electrical Design and Construction Standards for Chamber Type Substations
This Network Standard specifies Ausgrid’s requirements for the electrical design, construction and equipping of chamber type distribution substations, for supply of electricity to premises.
NSA2007 : Amending Network Standard NS128 Pole Installation and Removal
NS128 describes the requirements relating to the selection, handling, positioning, erection and removal of poles.
NSA2006 : Announcing Network Standard NS211 Annexure G - LV HRC Fuse Asbestos Product Guide
As part of Ausgrid’s ongoing asbestos maintenance program, independent Licenced Asbestos Assessors have identified Low Voltage HRC fuses of various types as potentially asbestos containing.
NSA2005 : Announcing Network Standard NS211 Annexure F - Asbestos Product Guide
This Product Guide is a collection of data sheets, each representing a unique asbestos-containing product which is often found on Ausgrid assets.
NSA2001: Announcing Network Standard NS272 - Underground Cable Rating
This Ausgrid Network Standard describes the requirements for undertaking steady-state rating calculations for underground cables that form part of the Ausgrid transmission and distribution cable network.
NSA2000: Amending Network Standard NS261 - Requirement for Design Compliance Framework for Network Standards
Amending Network Standard NS261, Requirements for Design Compliance Framework for Network Standards
NSA1999: Amending Network Standard NS181 - Approval of Materials and Equipment and Network Standard Variations
Amending Network Standard NS181, Approval of Materials & Equipment and Network Standard Variations
NSA1998: Amending Network Standard NS232 - Telecommunications Cables on Ausgrid Poles
This standard specifies the requirements for attachment of third-party telecommunications cable equipment to Ausgrid’s overhead electrical network.
NSA1996: Announcing Network Standard NS162 - Installation of Fibre Optic Communication Cables in Ausgrid Conduit Network and Substations
Announcing Network Standard NS162, Installation of Fibre Optic Communication Cables in Ausgrid Conduit Network and Substations
NSA1995: Amending Network Standard NS104 -Specification for Electrical Network Project Design Plans
Amending Network Standard NS104, Specification for Electrical Network Project Design Plans
NSA1994: Amending Network Standard NS195 - High Voltage Customer Connections (HVCs)
Amending Network Standard NS195, High Voltage Customer Connections (HVCs)
NSA1992: Amending Network Standard NS179 - Vegetation Management
To define Ausgrid’s requirements regarding management of vegetation in the vicinity of Ausgrid’s network assets.
NSA1991: Amending Network Standard NS200 - Major Substations Ventilation Design Standard
Network Standard NS200 provides the requirements for natural, mechanical and other types of ventilation to be considered and included into the design of major substations.
GI29_20 DERR Compliance Reminder Dec20 Final
: Compliance reminder to submit installed generation equipment information to AEMO’s Distributed Energy Resources (DER) Register.
GI28_20 Field Recording Changes
Advice to companies about Field Recording obligations. Ausgrid Field Recording Technical Guide and Network Standard have upcoming changes.